Safety considerations
The machine is intended to be operated by qualified personnel who are familiar with relevant safety requirements. Safety equipment necessary for the prevention of accidents at the mounting and operation of machine shall be applied at all times.
It is the duty of the safety officers in charge to make sure that all personnel operating the machine meet these demands.
The machines operate using electrical power. The transmission of these powers to the mechanical drum represents a certain danger and must be maintained continuously.

- It is advised to wear ear protection when operating machine.
- It is advised to apply an earth breaker device between electrical connection and machine to prevent accidents.
- Always make sure the equipment on machine is in good condition.
- Always disconnect the air or power supply when maintaining or working on the machine.
- Use only original Rustibus spare parts on the machine.
--- Always think safety first when operating machine.

Before starting the operation
Congratulations on your new Rustibus de-scaling machine. In order to ensure your full benefit and safety of operation we recommend you to read this operation manual carefully before starting. Always lift up machine in order for chain drum to rotate freely when starting the machine.

(i) Make sure all safety measurements are being considered.
(ii) Confirm correct voltage before connecting cable to supply.
(iii) Check oil level container for the air powered machine if applicable.
(iv) Start and stop the machine and check that rotation is correct according to marking on machine.
(v) Make sure the cable is properly connected and safely located for your operation.
(vi) Scaling can start. Run machine forward and backward to achieve the best result.
(vii) Do not run machine over sharp edges, but along these. The chain drum will last longer by working the machine with care.
(viii) If the operations of the machine tend to be too rough, the el. Motor may be overloaded and the thermal protection will disconnect power supply. If this occurs, wait for three minutes and push “0” button and the “1” button to start again. This
will reset the thermal relay.
(ix) When only two links are left on the chains, the drum should be removed from machine for replacement of chains.

WARNING

! Rotating equipment may cause serious injury – protect hands, feet, eyes and hearing.

! The Chain drum is rotating at high RPM, show outmost care when connecting cable, air hose or starting machine and when operating machine.
ALWAYS THINK SAFETY FIRST!

! Debris from scraping action may be scattered.

! Rustibus de-scaling machine may produce sparks.

! Respiratory protection should be considered depending on material being removed.

! Before starting Rustibus de-scaling machine, ensure that all fixing screws, bolts, fittings, driving wheel, chain head/drum are mounted correctly and securely tensioned. For more information, check the maintenance section of this manual.

! Never attempt to de-scale an area when its mechanical integrity is in doubt, according to ASME/API specifications or other applicable codes and standards.

 

CAUTION

! Never install, remove or perform any maintenance on the Rustibus de-scaling machine when the power supply is connected or running.

! ALWAYS lift up machine (push down the handle) in order for the chain drum to rotate freely when starting the machine.

! Always keep both hands on handles when operating the Rustibus de-scaling machine.

! Never use the Rustibus de-scaling machine in explosive areas due to potential to produce sparks.

! Never operate the Rustibus de-scaling machine while wearing loose hanging chains, hanging ID/security badges or garments that may be caught in the rotating parts.

! Never start the Rustibus de-scaling machine before it’s cables or hoses are properly secured and safely located.

! Rustibus de-scaling machine should be properly maintained and stored when not in use to avoid damage to parts.

 

The Company Company News Reference List Board of Directors
Rustibus Surface Preparation Equipment   - Rustibus Walk Behind Models   - Rustibus Handheld Scalers   - Rustibus Pipe Series   - Rustibus Vertical System   - Rustibus Cleaning Jet Air Treatment and Pneumatic Equipment   - Compressors   - Venturi Air Movers   - Pneumatic Jet fan   - Tank Style Air Manifolds   - In-line Lubricators   - Rustibus Air Pro   - Air Connections Safety Equipment   - Water Nozzle System   - Electric Earth Breaker   - Pneumatic Whip Check   - Rustibus P.P.E. Package
Large Area Surface De-scaling Mid-Size Area Surface De-scaling Spot Scaling Cargo Hold De-scaling & Cleaning Newbuild Package Ballast Tank Package Ventilation Lubrication Safety
X Singapore
We provide Rental Rustibus machines to be effectively used while vessel is in drydock or during lay-up.
Ex Singapore/Antwerp/
Rotterdam

Singapore Office:
+65 6262 5226
Contact us if you want to know more

X Antwerp / Rotterdam
The RVS is a revolutionary solution for de-scaling flat vertical surfaces, preferably for box shaped cargo holds or ships sides

Antwerp Office:
+32 3227 2096
Contact us if you want to know more

X Norway
Rustibus chain link technology ensures that no dimples are produced on steel and thus not damage it.

Norway Office:
+47 5618 1200
Contact us if you want to know more

X Houston
The Rustibus Pipe Series are a new range of mechanical machines designed for the sole purpose of de-scaling and cleaning outer pipe surfaces in one 360 operation.

Houston office:
+ 1 2816689330
Contact us if you want to know more